Laing LHB08100092 AutoCirc recirkulationspumpe med timer

Brand:Laing

3.3/5

kr
5218.69

PRODUKTBESKRIVELSE Autocirkulationspumpen er installeret under vasken eller vandhanen længst væk fra vandvarmeren - hvor varmt vand normalt tager længst tid at nå frem. En indbygget temperaturføler tænder automatisk for autocirkulationspumpen, når vandtemperaturen i varmtvandsforsyningsledningen køler ned til 85º F. Dette kolde vand i varmtvandsforsyningsledningen pumpes derefter ind i koldtvandsledningen og tilbage i vandet varmeapparat. Autocirkulationspumpen slukker automatisk, når varmtvandsforsyningsledningen til vandhanen når en temperatur på 95ºF, hvilket sikrer øjeblikkelig tilgængelighed af bruser varmt vand med maksimal temperatur varmt vand kun få sekunder efter. Når pumpen automatisk slukkes af den indbyggede termostat, forhindrer en automatisk lukkeanordning varmt eller koldt vand i at blande sig i begge forsyningsledninger. En anden fordel er, at varmt vand også øjeblikkeligt vil være tilgængeligt ved alle andre vandhaner i forsyningsledningen mellem vandvarmeren og vandhanen, hvor autocirkulationspumpen er installeret. Kræver ikke returledning. Kræver kun 14 watt strøm. Pakket komplet med en 6 fod lang strømledning. Kræver kun én pumpe og én installation til alle armaturer på varmtvandsrørledningen. Har indbygget fast termostat. Har en indbygget 24 timers timer, som tillader valg af systemdriftsperioder, der passer til familiens brug. Sparer den gennemsnitlige familie på fire op til 17.000 liter vand årligt. Langtidsholdbar, lydløs drift. Sparer energi, penge, vand og betaler sig selv på kort tid (se yderligere billeder for energisparediagram). Ingen aksel, ingen tætning. Vedligeholdelsesfri uden blokering. Enkelt lejet design. Modstandsdygtig over for kalkopbygning. FRA PRODUCENTEN Laing-pumpen er installeret under vasken eller vandhanen længst fra vandvarmeren - hvor varmt vand normalt tager længst tid at nå frem. En indbygget temperatursensor tænder automatisk pumpen, når vandtemperaturen i varmtvandsforsyningsledningen køler ned til 77º F. Dette kolde vand i varmtvandsforsyningsledningen pumpes derefter ind i koldtvandsledningen og tilbage i vandvarmeren . Laing-pumpen slukker automatisk, når varmtvandsforsyningsledningen til vandhanen når 91º F, hvilket sikrer øjeblikkelig tilgængelighed af bruser varmt vand med maksimal temperatur varmt vand kun sekunder efter. Når pumpen automatisk slukkes af den indbyggede termostat, forhindrer en automatisk lukkeanordning varmt eller koldt vand i at blande sig i begge forsyningsledninger. Produktet skal installeres af en autoriseret fagmand.

Sparer den gennemsnitlige familie på fire op til 17.000 liter vand årligt. Har en indbygget 24 timers timer, som tillader valg af systemdriftsperioder, der passer til familiens brug. Pakket komplet med en 6 fod lang strømledning. Støjniveau - Whisper quiet, mindre end 30 db. Kræver kun 14 watt strøm; Kræver ikke returledning. Autocirkulationspumpen ACT E1 er installeret under vasken eller vandhanen længst fra vandvarmeren.
Batteries Included? ‎No
Batteries Required? ‎No
Brand Laing
Color ----
Color ‎----
Country of Origin ‎China
Customer Reviews 4.2 4.2 out of 5 stars 534 ratings 4.2 out of 5 stars
Domestic Shipping Item can be shipped within U.S.
Included Components ‎----
International Shipping This item can be shipped to select countries outside of the U.S. Learn More
Is Discontinued By Manufacturer ‎No
Item Dimensions LxWxH 0.1 x 5 x 7.5 inches
Item model number ‎LHB08100092
Item Package Quantity ‎1
Item Weight ‎2.98 pounds
Manufacturer ‎Laing
Part Number ‎LHB08100092
Pattern ‎Pump
Power Source Corded Electric
Power Source ‎Corded Electric
Product Dimensions ‎0.1 x 5 x 7.5 inches
Special Features ‎Easy to Install, Quiet
Style Above Ground
Style ‎Above Ground
Voltage ‎115 Volts
Warranty Description ‎Warranted against defects in materials and workmanship for 2 years from the date of manufacture or 1 year from the date of user purchase, whichever is sooner.

3.3

2 Review
5 Star
64
4 Star
16
3 Star
7
2 Star
2
1 Star
12

Skriv din anmeldelse

Din e-mail vil ikke blive offentliggjort. Alle obligatoriske felter er markeret med*

Scritto da: Desert Dweller
Do your homework first!
I have to admit I was a bit skeptical about this device, but I've got a long run from the water heater to the bathroom sink. I thought about putting a little electric water heater tank under the sink, but then thought how it would do me no good for the shower, and for the other bathroom sink. I looked at a couple different devices. One was to be mounted by the hot water heater and involved a bit more plumbing than I'd prefer. It would certainly be easier to provide power to the unit in the unfinished area of the basement, so it's not a terrible idea. I believe that same unit or a similar one had a plastic housing - not among my preferred materials. The unit was REALLY easy to install under my bathroom sink. You will need to purchase at least two faucet supply lines. If your existing lines from shutoff valves to faucet are old, consider replacing them too. We ended up replacing old faucets at the same time. The new faucets The BIG lesson: I should have carefully figured which faucet is the last on the circuit. My logic told me the water would have come up from the finished basement directly to my spouse's sink, then over to mine and then to the shower. I should have taken a stopwatch to time hot water to each sink separately. As luck would have it, the water at my sink is nice and warm. Her sink is about 8 feet away and it takes another 15 seconds or so for the warm water to get to her once she turns her valve on. Same story with the shower. In both cases it's an improvement, but I clearly overcommitted to a solution that did not work as I imagined. Do your homework first! Second lesson: Sometimes an elegant solution can be better thought out. We're retired, so we don't have a real solid schedule for a morning or evening routine so I included a timer switch in the circuit. The timer switch allows me to immediately start the pump and let it run for a range of five minutes to four hours. I kind of like the approach and it works pretty well, with the exception of said spouse's access to hot water. The problem is that I decided (for some insane reason) to switch only the top outlet of the duplex pair. It resulted in too many wires in the box. Word to the wise - just switch the whole duplex or plan ahead for a deeper box. So, the routine is that the first one in the bath area in the morning or evening hits the switch to get the water circulating. Evening is easiest because we are more often in the bath area before bedtime. Hitting the 4 hour button works pretty good. The unit only consumes 13 watts, so it's not a big worry. I'm a bit more concerned about the radiator effect of the hot water circulating in the system. For those of you who are less obsessed with the absolute minimum pump time, just set the included timer for a reasonable time range in the morning and the evening. It will be just fine! One note: It takes somewhere around five minutes for the water to heat up at my sink. My assumption is the pump is not pushing a huge volume very quickly. The pump shuts off when the water reaches 91 degrees at my sink, so I assume the pump is coming on and off intermittently during my four hour evening window. Not a bad situation. In our area, sewer bills are directly related to water, so I expect we'll save on both bills. I doubt there will be a significant reduction, but feel conservation of water and reduction in sewer discharge is in all of our best interests. I have no qualms about recommending this Laing pump. The Laing web site will give you NO clues about where to purchase one. The big box stores don't stock them but you can order one from one of the big box stores. Amazon has the unit available and delivered in two days for the same price. I'd do this again if I need a retrofit unit in a house that does not have a dedicated return line to the water heater!
Scritto da: J2
Works As Designed
We had to wait several minutes for the water in kitchen sink to get warm, basically fill a two gallon bucket when I tested. This is very frustrating when you just want to wash your hands or rinse off a utensil. We explored cheaper options like putting a small hot water tank under the sink but even the smallest ones take up way too much room based on the measurements. We elected to go with this small pump unit because of the small size and because it would warm the water to other faucets in the house too. This pump does everything it was designed to do and works as expected. It is quiet and yes we can hear it running under the cupboard but it is not annoying at all. It was easy to plug in because we already had an outlet for a garbage disposal. We bought all new hoses and hooking these up was easy. When I first turned unit on I can hear it humming and working. It kept running and running for two to three times longer than if we were to run hot water out of the tap. It eventually shut off and I realized it just is not as much volume pushing through as if we turned on tap. No big deal at all and I was actually glad it isn’t pushing huge amounts of water through the line. I went to tap and it was immediately ready for use. No more waiting for water! I ran around and tested other sinks and they are all warm too! Now the water doesn’t come out piping hot after a cycle. Our water heater is set to a higher temp than the shut off setting on the pump. I understood this before purchase but the water is immediately usable. If you happen to catch it right after pump cycles it will be warmer. We don’t have a dedicated return line for the hot water so this was our best option and it performs as designed and the best it can do under the circumstances. Yes cold water is warmer now and we have to let it run for about two gallons to get back to normal cold temp. But we rarely go to sink wanting cold water. If we want cold water to drink we go to cold filtered water on refrigerator. So again without dedicated hot water return line there are sacrifices. There is a timer setting on the pump to tell it which hours of the day it will come on. There is a full on position to just run based on temperature of the water to tell it when to cycle and full off position. We leave it in full on. The other style pump from the manufacture has an adjustment to set the water temperature it comes on at. The instructions for this pump talk about that. The instructions say you can only set the on temperature and not the off temperature. So for that I am glad we didn’t spend the extra money on the other pump. This one works great! Edit: Added a smart plug to outlet so we could have more scheduling options between weekdays and weekends and night and day. Works great so far in not running when we are sleeping or letting run all day on weekends, but not weekdays. We can also ask Alexa to turn it on if we happen to be home during a workday and it is normally scheduled off. So there is some energy cost savings with this option.

Relaterede produkter

hot

Oplev vores internationale netværk

Vi sender til 28 lande, over 200.000 produkter. Hold dig opdateret, tilmeld dig nyhedsbrevet.

Array